Model |
FD-G50
|
Pipe size |
1 1/2", 1 1/4", 2.4 to 5.7 mm 0.09" to 0.22", 2", 32 A, 40 A, 50 A, ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44"
|
Supported pipe materials |
Iron, stainless steel, steel
|
Supported fluids |
Air, Nitrogen, other gases*1
|
Fluid temperature |
0 to 60ºC 32 to 140 °F
|
Recommended pressure |
0.4 MPa or greater (58 PSI or greater)
|
Rated velocity of flow range |
Up to 15 m/s
|
Actual flow rate range (typical) |
Pipe size 32 A: 32.00Pipe size 40 A: 42.00Pipe size 50 A: 70.00, Pipe size 32 A: 54.00Pipe size 40 A: 72.00Pipe size 50 A: 120.00, Pipe size 32 A: 900.0Pipe size 40 A: 1200.0Pipe size 50 A: 2000.0
|
Standard flow rate range (typical) [CFM] |
Pipe size 32 A: 151.58Pipe size 40 A: 198.95Pipe size 50 A: 331.58, Pipe size 32 A: 192.17Pipe size 40 A: 252.22Pipe size 50 A: 420.37, Pipe size 32 A: 232.76Pipe size 40 A: 305.49Pipe size 50 A: 509.16, Pipe size 32 A: 273.35Pipe size 40 A: 358.77Pipe size 50 A: 597.95
|
Display |
QVGA 2.2" LCD color monitor
|
Display update cycle |
Approx. 3 Hz
|
Display Resolution |
0.01 CFM, 0.01 m3, 0.01 m3/h, 0.1 CF, 0.1 L/min, 1 L
|
Response Time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
|
Measurement accuracy |
±1.0% of F.S.*2*3*4*5, ±2.0% of RD*2*3*4*5
|
Zero point error |
±0.15% of F.S.*2*6
|
Static leakage repeatability |
±1.0% of RD*4*7
|
Hysteresis |
Variable
|
Flow units |
CFM, CFM(S), L/min, L/min (N), L/min (S), m3/h, m3/h (N), m3/h (S)
|
I/O wiring connection port |
M12 4-pin connector (male)
|
Detection mode (switchable) |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8, Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8
|
Standard I/O (switchable) |
4 to 20 mA/0 to 20 mA, input time: 20 ms or more, load resistance: 500 Ω or less, max. 100 mA/ch, NPN/PNP setting switchable, open collector output 30 VDC or less, residual voltage: 2.5 V or less, Short-circuit current: 1.5 mA or less
|
Protection Circuit |
Power supply reverse connection protection, power supply surge protection, Short-circuit protection for each output, Surge protection for each output
|
Analog input (for volume conversion) |
analog current input (4 to 20 mA), input resistance: 100Ω or less, M8 4-pin connector (female)
|
Power supplied to pressure sensor |
Supply current:70 mA or less (analog output of the pressure sensor included), Supply voltage: Equivalent to voltage applied to the FD-G
|
Communication interface |
100 Mbps, Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable, D-code), IEEE 802.3u (100BASE-TX), M12 connector (female, USB 2.0
|
Network function |
EtherNet/IP™, IO-Link*9, Modbus TCP
|
Recording capacity |
100, Approx. 5 years
|
Power supply |
class 2, 20 to 30 VDC including 10% ripple (P-P), 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), 290 mA or less at 24 V, 350 mA or less at 20 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded), 490 mA or less at 24 V, 550 mA or less at 20 V
|
Environmental resistance |
10 to 500 Hz, 100 m/s2, 1000 times for each axis, 16 ms pulse, 5 to 85%RH (no condensation), Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing), IP65/67 (IEC 60529)*10, power spectral density: 0.816 G2/Hz, XYZ axes
|
material |
Body: PBT + coating, Body: PPS/SUS304, display: PMMA, Ethernet port: zinc nickel plating, Power supply port: SUS304-equivalent, rear surface: rubber, SUS304
|
Weight |
Approx. 2.7 kg
|