Model |
FD-G80L
|
Pipe size |
2 1/2", 2.0 to 4.0 mm 0.08" to 0.16", 3", 65 A, 80 A, ø72 to 78 mm 2.83" to 3.07", ø86 to 92 mm 3.39" to 3.62"
|
Supported pipe materials |
Iron, stainless steel, steel
|
Supported fluids |
Air, Nitrogen, other gases*1
|
Fluid temperature |
0 to 60ºC 32 to 140 °F
|
Recommended pressure |
0.4 MPa or greater (58 PSI or greater)
|
Rated velocity of flow range |
Up to 15 m/s
|
Actual flow rate range (typical) |
Pipe size 65 A: 120.00Pipe size 80 A: 160.00, Pipe size 65 A: 200.0Pipe size 80 A: 280.0, Pipe size 65 A: 3300Pipe size 80 A: 4600
|
Standard flow rate range (typical) [CFM] |
Pipe size 65 A: 1025.05Pipe size 80 A: 1366.73, Pipe size 65 A: 568.43Pipe size 80 A: 757.91, Pipe size 65 A: 720.64Pipe size 80 A: 960.85, Pipe size 65 A: 872.84Pipe size 80 A: 1163.79
|
Display |
QVGA 2.2" LCD color monitor
|
Display update cycle |
Approx. 3 Hz
|
Display Resolution |
0.01 CFM, 0.01 m3, 0.1 m3/h, 1 CF, 1 L, 1 L/min
|
Response Time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
|
Measurement accuracy |
±1.0% of F.S.*2*3*4*5, ±2.0% of RD*2*3*4*5
|
Zero point error |
±0.15% of F.S.*2*6
|
Static leakage repeatability |
±1.0% of RD*4*7
|
Hysteresis |
Variable
|
Flow units |
CFM, CFM(S), L/min, L/min (N), L/min (S), m3/h, m3/h (N), m3/h (S)
|
I/O wiring connection port |
M12 4-pin connector (male)
|
Detection mode (switchable) |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8, Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8
|
Standard I/O (switchable) |
4 to 20 mA/0 to 20 mA, input time: 20 ms or more, load resistance: 500 Ω or less, max. 100 mA/ch, NPN/PNP setting switchable, open collector output 30 VDC or less, residual voltage: 2.5 V or less, Short-circuit current: 1.5 mA or less
|
Protection Circuit |
Power supply reverse connection protection, power supply surge protection, Short-circuit protection for each output, Surge protection for each output
|
Analog input (for volume conversion) |
analog current input (4 to 20 mA), input resistance: 100Ω or less, M8 4-pin connector (female)
|
Power supplied to pressure sensor |
Supply current:70 mA or less (analog output of the pressure sensor included), Supply voltage: Equivalent to voltage applied to the FD-G
|
Communication interface |
100 Mbps, Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable, D-code), IEEE 802.3u (100BASE-TX), M12 connector (female, USB 2.0
|
Network function |
EtherNet/IP™, IO-Link*9, Modbus TCP
|
Recording capacity |
100, Approx. 5 years
|
Power supply |
class 2, 20 to 30 VDC including 10% ripple (P-P), 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), 290 mA or less at 24 V, 350 mA or less at 20 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded), 490 mA or less at 24 V, 550 mA or less at 20 V
|
Environmental resistance |
10 to 500 Hz, 100 m/s2, 1000 times for each axis, 16 ms pulse, 5 to 85%RH (no condensation), Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing), IP65/67 (IEC 60529)*10, power spectral density: 0.816 G2/Hz, XYZ axes
|
material |
Body: PBT + coating, Body: PPS/SUS304, display: PMMA, Ethernet port: zinc nickel plating, Power supply port: SUS304-equivalent, rear surface: rubber, SUS304
|
Weight |
Approx. 3.6 kg
|
Brand |
Keyence
|