Model |
NR-FV04 *1
|
Type |
Pulse measurement unit
|
Input method |
channels insulated from each other, input channels insulated from other units (PC), Insulated single-end input
|
Number of channels |
4 ch *2
|
Measurement cycle |
Maximum sampling cycle: 1 μs (1 MHz) to 60 s
|
A/D converting system |
simultaneous sampling of all channels, Successive approximation
|
A/D resolution |
14 bit
|
Input frequency band |
250 kHz (−3 dB or more)
|
Low pass filter |
PASS, 1.5 kHz, 15 kHz, 50 kHz
|
Pulse input |
+1 V, +10 V, +100 mV, +100 V, +2.5 V, +20 V, +250 mV, +5 V, +50 mV, +50 V, +500 mV, ±700 V *3, ×1.5, ×16), ×3, ×5, ×8, 0 V, 1 to 64 (Can be set to units of 1 division), 100 mV, 2 μs or more for both ON and OFF, 5 V, 50 mA or +5 V, 50 mANPN open-collector output connectable, 500 mV, AC falling edge, AC rising edge, AUTO, DC falling edge, DC rising edge, Dedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003; +12 V, Predictive calculation, pulse count (Single-phase input), Pulse count: None, Pulse frequency, Pulse frequency: Averaging rate of 1 to 32768 (automatically selected), sensor power supply not insulated from system bus, Stop prediction (OFF
|
Voltage input |
±10 V, ±100 V, ±2 V, ±20 V, ±5 V, ±50 V, ±700 V *3, 0.02% of F.S., 80 dB or more (at up to 60 Hz DC), AC, Averaging rate: 1 to 128 (automatically selected), DC, digital filter: ON); 0.05% of F.S., LPF: 1.5 kHz (200 μs/S, LPF: PASS
|
Measurement range |
000 counts/sampling cycle, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency), Display resolution: 0.1 mV, Display resolution: 0.2 mV, Display resolution: 0.5 mV, Display resolution: 1 count, Display resolution: 1 mV, Display resolution: 2 mV, Display resolution: 5 mV, Measurable range: −11.0000 to +11.0000 V, Measurable range: −110.000 to +110.000 V, Measurable range: −2.2000 to +2.2000 V, Measurable range: −22.000 to +22.000 V, Measurable range: −5.5000 to +5.5000 V, Measurable range: −55.000 to +55.000 V, Measurable range: 0 to 65, Measurable range: 0.05 to 16000.00 Hz
|
Measurement accuracy |
±0.01 Hz (20 Hz to 15 kHz, ±0.07% of rdg, ±0.1% of F.S., 20 ms/S, with digital filter ON)
|
Withstand voltage |
2200 VAC (50/60 Hz) for 1 minute
|
Connector format |
Insulated BNC connector
|
Input impedance |
1 MΩ ±1%, approx. 30 pF
|
Buffer memory |
16M data*4
|
Warm up time |
30 minutes or more
|
Maximum allowable voltage to ground |
[When using OP-35409 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II);[Direct input] Measurement terminal, GND terminal: 300 Vrms (CAT II);[When using OP-84266 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II);[When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC*3
|
Rating |
4 W or less (including OP-88003 sensor power supply)
|
Environmental resistance |
0 to +40°C 32°F to 104°F, 10 MΩ or more, 10 to 85% RH (no condensation), 500 VDC
|
Weight |
Approx. 270 g 9.53 oz
|
Brand |
Keyence
|