Model | MD-X2000A |
---|
Type | Marking unit (controller + head) 13 W Standard area |
---|
Software (sold separately) | Marking Diagnostic Tool), MB-PH1*1 (Marking Builder Plus |
---|
HMI console | MC-P1 |
---|
3D function add-in(sold separately) | MD-AD-3D |
---|
XY tracking add-in(sold separately) | MD-AD-XYT |
---|
Z tracking add-in(sold separately) | MD-AD-ZT |
---|
2D code reader add-in(sold separately) | MD-AD-2DR/MD-AD-2DRA |
---|
Marking method | XYZ 3-Axis simultaneous scanning method |
---|
Marking laser | 13 W, 1064 nm |
---|
Q-switch frequency | 1 to 400 kHz, CW (continuous wave) |
---|
Distance laser | FDA (CDRH) Part1040.10) *2, JIS6802, Semiconductor laser Wavelength: 683 nmOutput: 5.0 mWClass 3R laser product(IEC60825-1 |
---|
Guide laser/working distance pointer | FDA(CDRH) Part 1040.10) *2, JIS6802, Semiconductor laser, wavelength: 655 nmoutput: 1.0 mWClass 2 Laser Product(IEC60825-1 |
---|
Marking area | 125 × 125 × 42 mm 4.92" × 4.92" × 1.65" |
---|
Standard working distance(±variable width) | 189 mm (±21 mm) 7.44" (±0.83") |
---|
Marking resolution | 2 μm |
---|
Scan speed | Max. 12000 mm/s 472.44"/s |
---|
Charactertype | BMP/JPEG/PNG/TIFF, CODE39/ITF/2of5/NW7 (CODABAR)/JAN/CODE128/EAN/UPC-A/UPC-E/CODE93, Custom character font and logo (CAD) data, DataMatrix (ECC200/GS1 DataMatrix), GS1 DataBar/GS1 DataBar CC-A/GS1 DataBar Stacked/GS1 DataBar Stacked CC-A/GS1 DataBar Limited/GS1 DataBar Limited CC-A/GS1 DataBar Truncated/GS1 DataBar Truncated CC-A, hiragana, kanji), katakana, KEYENCE original font (numbers, letters, micro QR code, OpenType font *3, QR code, TrueType font, user font |
---|
Markingconditions | 0.1 to 125 mm 0.004" to 4.92", 2000 max., 256, encoder), Moving marking (constant, Stationary marking |
---|
Input/output | laser safety module control I/O *4, MIL connector I/O, Terminal block I/O |
---|
Interface | RS-232C/USB2.0/Ethernet (100BASE-TX/10BASE-T) *5 |
---|
Marking head installation direction | All directions |
---|
Marking head cable length | 4.3 ±0.1 m 14.1' ±0.3' |
---|
Cooling method | Forced air cooling |
---|
Applicable regulations | EN50581)/CSA standards and UL standards (CAN/CSA C22.2 No.61010-1, EN55011, EN60825-1, EN61000-6-2, EN62471, EU directives (EMC Directive, ICES-001 Class A)/China RoHS/UKCA, Low Voltage Directive, RoHS Directive)/EN standards (EN61010-1, UL61010-1)/North American regulations (FCC Part 15B |
---|
Rated voltage and power consumption | 100 to 240 VAC ±10% 50/60 Hz, 700 VA max. |
---|
Environmental resistance | -10 to 60°C 14 to 140°F (no freezing), 0 to 40°C 32 to 104°F, 2, 30 to 85% (no condensation), II, IP64 (marking head) |
---|
Weight | Controller: 23.0 kg 50.71 lbMarking head: 13.8 kg 30.42 lbConsole: 2.0 kg 4.41 lb |
---|