Model | FR-LEX20L |
---|
Type | 2-wire explosion-proof model |
---|
Measuring range | Up to 15 m 49.2'*1 |
---|
Display range | Up to 25 m 82.0'*1 |
---|
Measurable dielectric constant of medium | 2 or more *2 |
---|
Resolution | 1 mm 0.04" |
---|
Precision | Up to 0.1 m 0.3': ±10 mm 0.39";0.1 to 10 m 0.3' to 32.8' : ±1 mm 0.04";10 to 20 m 32.8' to 65.6': ±2 mm 0.08"*3 |
---|
Response Time | 1 s, 10 s, 25 s, 4 s (default value) |
---|
Tank pressure | -0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F) |
---|
material | chloroprene, Lens: PTFE;Internal seal: FFKM;Fastener: SUS304, NBRCable glands: Nickel-plated brass, PPS PC PA Internal potting agent: Epoxy resin(when using an Isolated barrier) Barrier: PC(when using a Zener barrier) Barrier: PC(when using a Zener barrier with a flameproof enclosure) Explosion-proo |
---|
Connection diameter | G1-1/2 (40A) |
---|
Output | ─, 4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response]) |
---|
Analog output accuracy | ±0.1 mA (zero point = 4 mA) *4, ±0.2 mA (full scale = 20 mA) *4, 1 mm 0.04"*4 |
---|
Power supply | 18.3 to 35 VDC.(when using an Isolated barrier) 24 VDC +25%/-10%(when using a Zener barrier) 20.1 to 28 VDC(when using a Zener barrier with a flameproof enclosure) 20.1 to 28 VDC, 752.5 mW or less (including analogue output; excluding load current)(when using an Isolated barrier) 3 W or less(when using a Zener barrier) 602 mW or less(when using a Zener barrier with a flameproof |
---|
Environmental resistance | -30 to +60°C -22 to 140°F (no freezing)(when using an Isolated barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing)(when using a Zener barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing)(wh, -30 to +85°C -22 to 185°F (no freezing), 10 to 500 Hz; Power spectral density: 0.816 G2 X, 100 m/s2 (10 G), 1000 times each in X, 16 ms pulses, Up to 85% RH (no condensation), Y and Z directions |
---|
IECEx | -30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof en, Ex ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da(when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC(when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC(when, Ui: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / L, Zone 0/20(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier) Do not install in a hazardous location (associated apparatus*5)(wh |
---|
ATEX and UKEX | -30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof en, II 1 G Ex ia IIC T4 Ga or II 1 G Ex ia IIB T4 Ga II 1 D Ex ia IIIC T135°C Da(when using an Isolated barrier) II (1) G [Ex ia Ga] IIC or II (1) G [Ex ia Ga] IIB II (1) D [Ex ia Da] IIIC(when using a Ze, Ui: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / L, Zone 0/20(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier) Do not install in a hazardous location (associated apparatus*5)(wh |
---|
Type Approval of Electrical Equipment for Use in Explosive Atmospheres | -30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof en, Ex ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da(when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC(when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC(when, Ui: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / L, Zone 0/20(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*5)(when using a Zener barrier) Do not install in a hazardous location (associated apparatus*5)(wh |
---|
NRTL/ACO | -30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F(when using an Isolated barrier) ─(when using a Zener barrier) ─(when using a Zener barrier with a flameproof enclosure) Explosion-proof en, AEx db [ia Ga] IIB T4 Gb/Zone 21, AEx ia IIB T4 Ga/Zone 20, AEx ia IIC T4 Ga/Zone 20, AEx ia IIIC T135°C Da/Class I, AEx tb [ia Da] IIIC T135°C Db/Class I, B, C, Class I, D, D or Class I, D/Class II, Division 1, Division 1 or Class I, Division 1(when using a Zener barrier with a flameproof enclosure) Class I, Division 1(when using a Zener barrier) [AEx ia Ga] IIB/[AEx ia Da] IIIC Intrinsically safe circuit for Class I, Division 1(when using an Isolated barrier) [AEx ia Ga] IIC or [AEx ia Ga] IIB/[AEx ia Da] IIIC Intrinsically safe circuit for Class I, F, G, G/Class III, Groups A, Groups C, Groups E, T135°C /Class III, T135°C/Class III, T4/Class II, Ui: 35 VDC / Ii: 142.4 mA / Pi: 1000 mW / Li: 26.2 nH / Ci: 79 nF(when using an Isolated barrier) Um: 250 VRMS / Uo: 26.78 VDC / Io: 115.307 mA / Po: 772 mW / Lo (IIC): 0.2 mH / Co (IIC): 0.092 μF / L, Zone 0, Zone 1, Zone 0/20 Division 1(when using an Isolated barrier) Do not install in a hazardous location (associated apparatus*6)(when using a Zener barrier) Do not install in a hazardous location (associated appa |
---|
enclosure rating | Enclosure Type 4X (NEMA250)(when using an Isolated barrier) Barrier: Not specified(when using a Zener barrier) Barrier: Not specified(when using a Zener barrier with a flameproof enclosure) Explosion-, IP67 (IEC60529) |
---|
Protection Circuit | power supply surge protection, Reverse power connection protection |
---|
Weight | Approx. 920 g 32.45 oz(when using an Isolated barrier) Barrier: Approx. 320 g 11.28 oz(when using a Zener barrier) Barrier: Approx. 100 g 3.52 oz(when using a Zener barrier with a flameproof enclosure |
---|
Brand | Keyence |
---|