OP-88200 Keyence Clamp-on Flow Meter
Product information
- Model
OP-88200
- Type
Convert screw adapter
- Number included
1 Piece
- material
Brass nickel plating FKM
- Weight
Approx. 30 g
- Brand
Keyence
Showing 91–120 of 241 results
OP-88200
Convert screw adapter
1 Piece
Brass nickel plating FKM
Approx. 30 g
Keyence
OP-88201
Convert screw adapter
1 Piece
Brass nickel plating FKM
Approx. 35 g
Keyence
FD-EPA0
Zero line type*1
─*2
─
─*2
No cable
2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, 50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 2.5 ms) *3, initial value: 250 ms) *3
FD-EPA1
Cable Type
3
1
2
2 m 6.6', 8 cores, strand wire
2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, 50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 2.5 ms) *1, initial value: 250 ms) *1
FD-EPA1C
M12 connector type*1
3
1
2
100 mm 3.94", 8 pins, M12 connector, Pigtail
2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, 50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 2.5 ms) *2, initial value: 250 ms) *2
FD-EPH10
10.0 ±0.08 mm0.39" ±0.003", 10.0 ±0.15 mm0.39" ±0.006", ø10 0.39" *1, Resin pipe connectible to a one-touch coupling
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, 1050 L/min 37.1 CFM, 150 L/min 5.30 CFM, 450 L/min 15.9 CFM, 750 L/min 26.5 CFM, Response time of 250 ms: ±2.5% of F.S.*3*5
FD-EPH12
Resin pipe connectible to a one-touch coupling, 12.0 ±0.1 mm0.47" ±0.004", 12.0 ±0.15 mm0.47" ±0.006", ø12 0.47" *1
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, 750 L/min 26.5 CFM, Response time of 250 ms: ±2.5% of F.S.*3*5, 1250 L/min 44.1 CFM, 1750 L/min 61.8 CFM, 250 L/min 8.83 CFM
FD-EPH13
Resin pipe connectible to a one-touch coupling, 1/2” (Approx.12.7 mm 0.50") *1, 12.7 ±0.1 mm0.50" ±0.004", 12.7 ±0.15 mm0.50" ±0.006"
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, 750 L/min 26.5 CFM, Response time of 250 ms: ±2.5% of F.S.*3*5, 1250 L/min 44.1 CFM, 1750 L/min 61.8 CFM, 250 L/min 8.83 CFM
FD-EPH4
Resin pipe connectible to a one-touch coupling, 4.0 ±0.08 mm0.16" ±0.003", 4.0 ±0.1 mm0.16" ±0.004", ø4 0.16" *1
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, Response time of 250 ms: ±2.5% of F.S.*3*5, 125 L/min 4.41 CFM, 175 L/min 6.18 CFM, 25 L/min 0.88 CFM, 75 L/min 2.65 CFM
FD-EPH5
Resin pipe connectible to a one-touch coupling, 3/16” (Approx.4.76 mm 0.19") *1, 4.76 ±0.1 mm0.19" ±0.004", 4.76 ±0.15 mm0.19" ±0.006"
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, 150 L/min 5.30 CFM, Response time of 250 ms: ±2.5% of F.S.*3*5, 210 L/min 7.41 CFM, 30 L/min 1.06 CFM, 90 L/min 3.18 CFM
FD-EPH6
Resin pipe connectible to a one-touch coupling, 6.0 ±0.08 mm0.24" ±0.003", 6.0 ±0.1 mm0.24" ±0.004", ø6 0.24" *1
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, Response time of 250 ms: ±2.5% of F.S.*3*5, 180 L/min 6.35 CFM, 300 L/min 10.59 CFM, 420 L/min 14.8 CFM, 60 L/min 2.12 CFM
FD-EPH7
Resin pipe connectible to a one-touch coupling, 1/4” (Approx.6.35 mm 0.25") *1, 6.35 ±0.1 mm0.25" ±0.004", 6.35 ±0.15 mm0.25" ±0.006"
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, Response time of 250 ms: ±2.5% of F.S.*3*5, 180 L/min 6.35 CFM, 300 L/min 10.59 CFM, 420 L/min 14.8 CFM, 60 L/min 2.12 CFM
FD-EPH8
Resin pipe connectible to a one-touch coupling, 8.0 ±0.08 mm0.31" ±0.003", 8.0 ±0.1 mm0.31" ±0.004", ø8 0.31" *1
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, Response time of 250 ms: ±2.5% of F.S.*3*5, 100 L/min 3.53 CFM, 300 L/min 10.59 CFM, 500 L/min 17.7 CFM, 700 L/min 24.7 CFM
FD-EPH9
Resin pipe connectible to a one-touch coupling, 3/8” (Approx.9.53 mm 0.38") *1, 9.53 ±0.1 mm0.38" ±0.004", 9.53 ±0.15 mm0.38" ±0.006"
Air, and non-corrosive gases*2, argon, nitrogen
−10°C to +60°C 14 to 140°F
1 MPa
Ultrasonic transmission time difference method
±(2.0% of RD+1.0% of F.S.)*3*4, 1050 L/min 37.1 CFM, 150 L/min 5.30 CFM, 450 L/min 15.9 CFM, 750 L/min 26.5 CFM, Response time of 250 ms: ±2.5% of F.S.*3*5
OP-88804
8-pin, Dedicated power supply cable M12, Standard
2 m 6.6'
Keyence
OP-88922
8-pin, Dedicated power supply cable M12, Standard
10 m 32.8'
Keyence
OP-88923
8-pin female to 8 pin male, Dedicated power supply cable M12, extention
3 m 9.8'
Keyence
OP-88924
8-pin female to 8 pin male, Dedicated power supply cable M12, extention
5 m 16.4'
Keyence
OP-88925
8-pin female to 8 pin male, Dedicated power supply cable M12, extention
10 m 32.8'
Keyence
FD-EPB1
For sensor heads compatible with ø4 0.16" to1/4” (FD-EPH4/EPH5/EPH6/EPH7)
Keyence
FD-EPB2
For sensor heads compatible with ø8 0.31"(FD-EPH8)
Keyence
FD-EPB3
For sensor heads compatible with 3/8” to 1/2”(FD-EPH9/EPH10/EPH12/EPH13)
Keyence
FD-ECA0
Zero line type*1
─*2
─
─*2
No cable
50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms)*3
FD-ECA1
Cable Type
2
1
2 m 6.6', 6 cores, strand wire
50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms)*1
100 mA or less total for two outputs, Instantaneous flow/Accumulated flow/Alarm output/Pulse outputNPN/PNP setting switchable, Instantaneous flow4-20 mA/0-20 mA (switchable), load resistance: 260 Ω or less, residual voltage: 2.5 V or less, Zero flow/Origin adjust./Reset totalShort-circuit current: 1.5 mA or less
FD-ECA1C
M12 connector type*1
2
1
100 mm 3.94", 8 pins of which 6 are used pins used, M12 connector, Pigtail
50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms)*2
100 mA or less total for two outputs, Instantaneous flow/Accumulated flow/Alarm output/Pulse outputNPN/PNP setting switchable, Instantaneous flow4-20 mA/0-20 mA (switchable), load resistance: 260 Ω or less, residual voltage: 2.5 V or less, Zero flow/Origin adjust./Reset totalShort-circuit current: 1.5 mA or less
FD-ECH10
*1 other*2, 10.0 0.39"± 0.15 mm 0.01", nylon, ø10 0.39", PFA, Polyurethane
Air, argon, nitrogen, and other gases*3
−10°C to +60°C 14 to 140°F
0 to 0.75 MPa (upper limit depends on pipe specifications)
Ultrasonic transmission time difference method
120 L/min 4.24 CFM * Initial display, 360 L/min12.7 CFM, 600 L/min21.2 CFM, 840 L/min29.7 CFM
FD-ECH12
*1 other*2, 12.0 0.47"± 0.15 mm 0.01", nylon, ø12 0.47", PFA, Polyurethane
Air, argon, nitrogen, and other gases*3
−10°C to +60°C 14 to 140°F
0 to 0.75 MPa (upper limit depends on pipe specifications)
Ultrasonic transmission time difference method
1260 L/min44.5 CFM, 180 L/min 6.35 CFM * Initial display, 540 L/min19.1 CFM, 900 L/min31.8 CFM
FD-ECH13
*1 other*2, 1/2" (approx. 12.7 mm 0.50"), 12.7 0.50"± 0.15 mm 0.01", nylon, PFA, Polyurethane
Air, argon, nitrogen, and other gases*3
−10°C to +60°C 14 to 140°F
0 to 0.75 MPa (upper limit depends on pipe specifications)
Ultrasonic transmission time difference method
600 L/min21.2 CFM, 1000 L/min35.3 CFM, 1400 L/min49.4 CFM, 200 L/min 7.06 CFM * Initial display
No worries. Our team is here to help you find the perfect part for your car. Just provide us with some details and we will get to work!