| Model | FD-MZ100AYKP*1 |
|---|
| Type | Horizontal |
|---|
| Shape | Built-in amplifier |
|---|
| Rated flow range | 1.4 – 26.0 G/min (5.0 – 100 L/min)*1 |
|---|
| Possible display range | 1.4 – 52.8 G/min (5.0 – 200 L/min)*2 |
|---|
| Possible ranges to set | 0 – 52.8 G/min (0 – 200 L/min) |
|---|
| Connection port | NPT1 (25 A) |
|---|
| Detectable fluids | Water or non-corrosive liquid |
|---|
| Conductivity of detection fluids | 5 µS/cm or higher |
|---|
| Detection fluid temperature | 0 to +85°C 32 to 185 °F (No freezing) |
|---|
| Pressure loss | Max. 1.45 PSI (0.01 MPa) |
|---|
| Display method | 7 segment LED, bar display (2 colors), dual row display with 4-digit, flow indicator, output indicators |
|---|
| Display Resolution | 0.1/1 (G/min, L/min) selectable |
|---|
| Repeatability | 0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 10 s : ±1% of F.S., 2.5 s : ±2.5% of F.S., 30 s : ±0.8% of F.S., 5 s : ±1.6% of F.S., 60 s : ±0.6% of F.S.*3 |
|---|
| Hysteresis | Variable |
|---|
| Response time (chatter prevention feature) | 0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable |
|---|
| Accumulated flow unit | 0.1/1/10/100/1000 (G, L) selectable |
|---|
| Integration data storage cycle | Save to memory every 10 seconds |
|---|
| Memory backup | Data read/write frequency : 1 million times or more), EEPROM (Data storage length : 10 years or longer |
|---|
| Control output/Accumulation pulse output/ Error alarm output | 3 outputs (N.O./N.C. switchable), max. 100 mA/ch*4 30 V or less, PNP open collector, residual voltage 1 V or less |
|---|
| Analog output | 4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value |
|---|
| Integration reset/bank switch input/flow zero function input | Input time : 20 ms or greater, Select either the accumulation output or the accumulation pulse by setting the mode |
|---|
| Minimum flow volume | 1.4 G/min (5 L/min)*5 |
|---|
| Power consumption (Current consumption) | Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA) |
|---|
| Rating | 24 VDC, Class 2, Ripple (P-P) 10 % or less |
|---|
| Environmental resistance | Y, 0 to +50 °C 32 to 122 °F (No freezing), 10 to 55 Hz, 2 hours in each of the X, 290 PSI (2.0 MPa), 35 to 85 % RH (No condensation), and Z directions, Double amplitude 1.5 mm 0.06", IP65, Max. 145 PSI (1.0 MPa) |
|---|
| material | Bore : SCS13, Cable : PVC, Measurement pipe : PPS, Metal case areas : SUS430, O ring : fluoro-rubber (FKM), Plastic case areas : PPS |
|---|
| Accessory | Connector cable (2.7 m 106.3"), Instruction Manual |
|---|
| Weight | 340 g, Approx. 1 |
|---|
| Brand | Keyence |
|---|