QD81DL96- 221934 Mitsubishi
SKU: QD81DL96Product information
- Series
MELSEC-Q SERIES
- Type
HIGH-SPEED DATA LOGGER MODULE
- Depth (mm)
90
- Weight (kg)
15
- Width (mm)
27, 4
- Height (mm)
98
- CE
COMPLIANT
Showing 1–30 of 63 results
MELSEC-Q SERIES
HIGH-SPEED DATA LOGGER MODULE
90
15
27, 4
98
COMPLIANT
NR-X100W
50M data*1
SD card (SD/SDHC)*2
100Base-TX (AUTO MDI/MDIX supported) *3, Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3, RJ45 connector, Simultaneous USB connection from one PC to up to four units (switchable by ID switch), USB 2.0 High-speed–compliant, USB mini-B connector
FTP client function, FTP server function, SNTP client function
Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection
B port)Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable), Dedicated remote connection connector × 2 (Remote OUT A port
NR-XCP30
240 × 320 dot, 3.5" TFT color LCD
NR-X100W*1
Chinese (Simplified), English, Japanese
1.6 W or less
0 to +40°C 32°F to 104°F, 10 to 85% RH (no condensation)
Approx. 290 g 10.24 oz
NR-C512*1
CAN Ver. 2.0B, High speed: 60 kbps to 1 MbpsSingle wire: 20 to 83.3 kbps, High speed: ISO 11898Single wire: SAE J2411
1 port*2, 9-pin D-sub male
128 messages/port, 512 signals (ch)/port
Maximum sampling cycle: 200 µs
100 mA external power supply required, High speed: 5 V internal supplySingle wire: +6.5 to +18 V
High speed: 120 Ω × 2 (enabled/disabled with DIP switch)Single wire: 9.1 kΩ
NR-CA04 *1
Acceleration measurement unit
channels not insulated from each other; input channels switchable between insulated and not insulated from other units (PC), Charge output sensor input / Single-end input
4 ch*2
Maximum sampling cycle: 10 µs (100 kHz) to 60 s
Delta-sigma method, simultaneous sampling of all channels
24 bit
NR-EN16
CL-3000 Series, DL-EN1 (Connected sensor: GT2 Series, FD-EC Series, FD-EP Series, FD-G Series, FD-H Series, FD-R Series, FD-X Series, FI-1000, FI-T Series)*1;LK-G5000 Series, FL Series, GP-M Series, GT Series, IB Series, IG Series, IL Series, IX Series, LJ-V7000 Series, LJ‑X8000 Series, LR-T Series, LS-9000 Series;Connection of one of the above devices per NR-EN16 allowed, SK Series)*1NQ-EP4L (Connected sensor: FD-Q Series
Automatic identification or manual identification by specifying the IP address
BOOTP/DHCP client supported (compatible with the above connection target devices), Ethernet TCP/UDP communication
1 port*2, Ethernet 100Base-TX (AUTO-MDI/MDIX-compatible)
16 ch max. (varies depending on connected devices)
Maximum sampling cycle: 1 ms (1 kHz) to 60 sWith effective rate display function for communication between connected sensors*3
NR-FV04 *1
Pulse measurement unit
channels insulated from each other, input channels insulated from other units (PC), Insulated single-end input
4 ch *2
Maximum sampling cycle: 1 μs (1 MHz) to 60 s
simultaneous sampling of all channels, Successive approximation
14 bit
NR-HA08 *1
High-speed analog measurement unit
input channels insulated from other units (PC), Single-ended input / Balanced differential input selectionChannels not insulated from each other
Single-end: 8 ch*2 (Differential: 4 ch) / Current: 4 ch*3
Maximum sampling cycle: 1 μs (1 MHz) to 60 s
Successive approximation
14 bit
NR-HA08P *1
input channels insulated from other units (PC), Single-end input / Balanced differential input selectionChannels not insulated from each other
Single-end: 8 ch*2 (Differential: 4 ch) / Current: 4 ch*3
Maximum sampling cycle: 1 μs (1 MHz) to 60 s
Successive approximation
14 bit
250 kHz (−3 dB typ.)
NR-HV04 *1
High-speed, high-voltage measurement unit
channels insulated from each other, input channels insulated from other units (PC), Insulated single-end input
4 ch *2
Maximum sampling cycle: 1 μs (1 MHz) to 60 s
simultaneous sampling of all channels, Successive approximation
14 bit
NR-ST04 *1*2
Strain measurement unit
Balanced differential input, channels not insulated from each other, input channels insulated from other units (PC)
4 ch *3
Maximum sampling cycle: 20 μs (50 kHz) to 60 s
simultaneous sampling of all channels, Successive approximation
16 bit
NR-TH08 *1
High-accuracy temperature/voltage measurement unit
CH inputs insulated from other units (PC), channels insulated from each other, channels not insulated from each other for resistance thermometers, Floating unbalanced input
Input: 8 *2
Fastest sampling cycle: 100 ms (A/D integration time: 2 ms) to 1 h
Delta-sigma method
24 bit
NR-TH08P *1
channels insulated from each other, Floating unbalanced input, inputs insulated from other units (PC)
Input: 8 *2
Fastest sampling cycle of 100 ms (A/D integration time: 2 ms) to 1 h
Delta-sigma method
24 bit
16.7 ms, 2 ms, 20 ms
NR-XHA08T
channels insulated from each other, input channels insulated from the case and other units (system), Insulated single-end input
8*1
Dedicated 3-pin connector
Maximum sampling cycle: 100 μs (10 kHz) to 60 s
Delta-sigma method
24 bits
NR-XR01
Dedicated remote input port × 1 (Remote IN), Output port × 1 (Remote OUT)Connection to NR-X100W master data collection unit or other NR-XR01 remote units using a remote unit cableDaisy-chain connections of multiple remote units allowed*1
Max. 8 units*2
Max. 100 kHz for all acquisition channels*3
±1 μs or less*4
Approx. 2.9 W
0 to +40°C 32°F to 104°F, 10 to 85% RH (no condensation)
NR-XTH08T
channels insulated from each other, input channels insulated from the case and other units (system), Insulated single-end input
8*1
Miniature thermocouple connector (Universal type)
Maximum sampling cycle: 10 ms (100 Hz) to 1 h
Delta-sigma method
24 bits
NR-XU15A
Dedicated lithium-ion battery pack NR-XB1 Series × 2
30% or more remaining: Green, Battery operation: Blue, Less than 30% remaining: Red, No remaining battery: OffIndividual displays for 2 battery slots, With NR-X100W battery power: Green
Number of connected units / Power consumption: 1 With 1 battery: Approx. 340 min., Number of connected units / Power consumption: 1 With 1 battery: Approx. 370 min., Number of connected units / Power consumption: 1 With 1 battery: Approx. 480 min., Number of connected units / Power consumption: 1 With 1 battery: Approx. 510 min., Number of connected units / Power consumption: At 10 W With 1 battery: Approx. 160 min., Number of connected units / Power consumption: At 10 W With 1 battery: Approx. 190 min., With 2 batteries: Approx. 1020 min.Number of connected units / Power consumption: 4 With 1 battery: Approx. 300 min., With 2 batteries: Approx. 140 min.Number of connected units / Power consumption: At 50 W (max. configuration) With 1 battery: Approx. 40 min., With 2 batteries: Approx. 220 min.*1, With 2 batteries: Approx. 320 min.Number of connected units / Power consumption: At 30 W With 1 battery: Approx. 70 min., With 2 batteries: Approx. 380 min.Number of connected units / Power consumption: At 20 W (max. configuration) With 1 battery: Approx. 110 min., With 2 batteries: Approx. 400 min.*1, With 2 batteries: Approx. 520 min.*1*2, With 2 batteries: Approx. 600 min.Number of connected units / Power consumption: 8 With 1 battery: Approx. 200 min., With 2 batteries: Approx. 680 min.Number of connected units / Power consumption: 5 With 1 battery: Approx. 110 min., With 2 batteries: Approx. 740 min.Number of connected units / Power consumption: 6 With 1 battery: Approx. 110 min., With 2 batteries: Approx. 80 min.*1, With 2 batteries: Approx. 960 min.Number of connected units / Power consumption: 4 With 1 battery: Approx. 260 min.
0 to +40°C 32°F to 104°F*3, 10 to 85% RH (no condensation)
Approx. 370 g 13.06 oz (Not including NR-XB1A)
Keyence
OP-24777
Analog input probe*1 (2-channel differential input)
120 cm
Keyence
OP-71802
1000 V DC + AC peak
10 MΩ ±1%
150 cm
1000 V (CAT II)* When connected to NR-HV04/NR-FV04Measurement terminal 700 Vrms (CAT II), GND terminal 300 Vrms (CAT II)
18 pF ±2 pF
15 pF to 45 pF
OP-88998
1000 V DC + AC peak
1000 V (CAT II)* When connected to NR-HV04/NR-FV04Measurement terminal 700 Vrms (CAT II), GND terminal 300 Vrms (CAT II)
10 MΩ ±1%
18 pF ±2 pF
15 pF to 45 pF
10:1 ±2%
NR-XH1W *1
NR-X100W/NR-500
Chinese (Simplified), English, Japanese
File Viewer X, LAN TOOL X, WAVE LOGGER X
Automation server (WAVE LOGGER X)
Equipped with a 100 Base-TX interface *3, Equipped with a USB 2.0 host (Type-A) interface*2, IEEE 802.11b/g/n (with NR-XW1) *3
Windows 10 Home/Pro/Enterprise or Windows 7 SP1 Home Premium/Professional/Ultimate (pre-installed)*4, Windows 11 Home/Pro
OP-24422
Differential input cable (Optional accessory)
10 m 32.8'
Keyence
OP-29371
Logic input probe
Analog input probe (2-channel singleend input)
2
120 cm
Keyence
OP-51583
26-pin terminal block cable
45 cm
Keyence
No worries. Our team is here to help you find the perfect part for your car. Just provide us with some details and we will get to work!